本页是为了通知蔡司眼科诊断仪器的所有者有关。
微软Windows打印线轴漏洞CVE-2021-34527("PrintNightmare")网络安全更新
"PrintNightmare" 是一个会影响安装有微软 Windows 操作系统的设备的安全漏洞。据微软证实,“当 Windows Print Spooler 服务以特定权限执行不允许的文件操作时,存在一个与远程代码执行相关的安全漏洞。攻击者可利用此安全漏洞使用系统权限执行任意代码。然后可以安装程序,显示、更改或删除数据,或创建用户权限不受限制的新帐户。”
虽然 "PrintNightmare" 不会影响 ZEISS 产品 的安全性和功能性,但我们仍为您的设备提供安全更新(补丁),以修复 "PrintNightmare" 安全漏洞。
蔡司已检查安全漏洞对安装有Windows操作系统的蔡司产品会产生哪些影响。仅下列产品需要更新。
相应的更新安装说明请参阅下表,以便能够修复您蔡司设备上的安全漏洞。如果您在更新蔡司设备时需要帮助,请联系本地支持团队。
-
ModelOSLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS CIRRUS
ZEISS CIRRUS 500/5000/6000
Windows 10ZEISS CIRRUS 400/4000/500/5000Windows 7
Follow instructions (see column to the left titled “Link to Instructions for Updating ZEISS Device”) -
ModelOSLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS CIRRUS photo 600/800ZEISS CIRRUS photo 600/800Windows 10ZEISS CIRRUS photo 600/800Windows 7Follow instructions (see column to the left titled “Link to Instructions for Updating ZEISS Device”)
-
ModelOSLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS ATLAS 9000
ZEISS ATLAS 9000
Windows 10ZEISS ATLAS 9000Windows 7Follow instructions (see column to the left titled “Link to Instructions for Updating ZEISS Device”) -
ModelOSLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS CLARUS 500/700ZEISS CLARUS 500/700Windows 10
-
ModelOSLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS HFA3ZEISS HFA3Windows 10
Microsoft Windows Print Spooler Vulnerability CVE-2021-34527 (“PrintNightmare“) Cybersecurity Update For Windows 10 OS
Note: the HFA3 is shipped with the instrument running in kiosk mode. To install the patch, disable Kiosk mode (Refer to instructions in the HFA3 IFU to access the Windows desktop), login as the IT Administrator user, run the “Kiosk OFF” shortcut on the desktop, and reboot the instrument.Windows 7Microsoft Windows Print Spooler Vulnerability CVE-2021-34527 (“PrintNightmare“) Cybersecurity Update For Windows 7 OS
Note: the HFA3 is shipped with the instrument running in kiosk mode. To install the patch, disable Kiosk mode (Refer to instructions in the HFA3 IFU to access the Windows desktop), login as the IT Administrator user, run the “Kiosk OFF” shortcut on the desktop, and reboot the instrument.Follow instructions (see column to the left titled “Link to Instructions for Updating ZEISS Device”) -
ModelOSLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS PLEX Elite 9000ZEISS PLEX Elite 9000Windows 10ZEISS PLEX Elite 9000Windows 7Follow instructions (see column to the left titled “Link to Instructions for Updating ZEISS Device”)
-
ModelOSLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS PRIMUS 200ZEISS PRIMUS 200Windows 10: serial numbers starting with 200-3XXXX and 200-5XXXXZEISS PRIMUS 200Windows 7: serial numbers starting with 200-0XXXX and 200-2XXXXPlease contact your Service TechnicianN/A
-
ModelOSLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS IOLMasterZEISS IOLMaster 5006. Generation, WinPOSZEISS IOLMaster 5.5ZEISS IOLMaster 700
-
ModelLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS SL Imaging Solution
ZEISS SL Imaging Solution
3 Files to download (unpack from zip):
- Install_Patch_PrinterNightmare_CVE-2021-34527_ Win-10.cmd
- LGPO.exe
- PrintNightmare_1.lgpo.txt
-
ModelLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS SL Workstation
ZEISS SL Workstation
3 Files to download (unpack from zip):
- Install_Patch_PrinterNightmare_CVE-2021-34527_ Win-7.cmd
- LGPO.exe
- PrintNightmare_1.lgpo.txt
-
ModelOSLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS VISUCAMZEISS VISUCAM 224ZEISS VISUCAM 524ZEISS Visucam 200
Computer 1969-629
ZEISS VISUCAM PRO NM 2ZEISS VISUCAM NM/FA 2ZEISS VISUCAM 500 -
ModelLink to Instructions for Updating ZEISS DeviceLink to Download (use Internet Explorer or Edge)ZEISS VISUPACZEISS VISUPAC 500
3 Files to download (unpack from zip):
- Install_Patch_PrinterNightmare_CVE-2021-34527_ Win-7.cmd
- LGPO.exe
- PrintNightmare_1.lgpo.txt