![]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.100.100.313,0,2188,1875.file/intrabeam-600-1-2.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.360.360.313,0,2188,1875.file/intrabeam-600-1-2.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.768.768.313,0,2188,1875.file/intrabeam-600-1-2.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.1024.1024.313,0,2188,1875.file/intrabeam-600-1-2.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.1280.1280.313,0,2188,1875.file/intrabeam-600-1-2.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.1440.1440.313,0,2188,1875.file/intrabeam-600-1-2.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.1875.1875.313,0,2188,1875.file/intrabeam-600-1-2.jpg"})
![]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.100.100.313,0,2188,1875.file/intrabeam-600-2-2.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.360.360.313,0,2188,1875.file/intrabeam-600-2-2.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.768.768.313,0,2188,1875.file/intrabeam-600-2-2.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.1024.1024.313,0,2188,1875.file/intrabeam-600-2-2.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.1280.1280.313,0,2188,1875.file/intrabeam-600-2-2.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.1440.1440.313,0,2188,1875.file/intrabeam-600-2-2.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.1875.1875.313,0,2188,1875.file/intrabeam-600-2-2.jpg"})
Specifications
ZEISS INTRABEAM Workplace
Total weight with full configuration
|
max. 155 kg (341.72lbs)
|
---|---|
Dimensions
|
900 mm x 1690 mm x 600 mm / 35.43" x 66.54" x 23.62"
(width x height x depth) |
Nominal voltage ranges, switchable
|
(115 V) 110 V – 125 V
(230 V) 220 V – 240 V |
Rated frequency
|
50 Hz – 60 Hz
|
Connected load
|
300 VA
|
Specifications
Control Console 600
Weight
|
4.50 kg (9.92lbs)
|
---|---|
Dimensions
|
305 mm x 89 mm x 381 mm / 12.00" x 3.50" x 15.00"
(width x height x depth) |
Power connection
|
Via workplace isolating transformer
|
Input voltage
|
100 V - 240 V
|
Rated frequency
|
50 Hz – 60 Hz
|
Power consumption
|
60 VA
|
Selectable operating parameters: |
40 kV / 40 μA
50 kV / 5, 1 0, 20 or 40 μA is the maximum current of the X-ray tube over the entire voltage range. |
![]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.100.100.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.360.360.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.768.768.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.1024.1024.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.1280.1280.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.1440.1440.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.1875.1875.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg"})
![]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.100.100.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.360.360.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.768.768.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.1024.1024.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.1280.1280.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.1440.1440.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.1875.1875.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg"})
Specifications
NC32 INTRABEAM Floor Stand
Rated voltage
|
100 V / 115 V / 230 V
|
---|---|
Rated frequency
|
50 - 60 Hz
|
Power consumption
|
max. 400 VA
|
Electrical standard
|
IEC 60601-1;
CAN/CSA-C22.2 No. 601.1-M90 |
Product classification
|
Type B
|
Case protection
|
IPX0
|
Protection class
|
Protection class I
|
Notice: The information provided shows only an extract of the instructions for use. For additional information please consult the appropriate instructions for use in full.