ZEISS CT LUCIA 621P
Treating a wide range of cataract patients with a unique ZEISS Optic.
CT LUCIA® 621P IOLs, with ZEISS Optic features, are designed to reduce spherical aberration and at the same time optimize visual outcomes in the event of potential decentration and lens misalignments.
The IOL features a reinforced optic-haptic junction, coupled with step-vaulted C-loop haptics, designed to enable easy centering while maximizing direct capsular contact, thus optimizing stability and supporting a consistent position in the bag. The ZEISS CT LUCIA 621P is supplied in a fully preloaded delivery system.
ZEISS CT LUCIA 621P
New generation of aspheric monofocal C-loop IOL
- Patented ZEISS Optic (ZO) Asphericity Concept
- Hydrophobic acrylic with heparin-coated2 surface
- Long-term optical clarity due to the glistening-free3 material
- Wide Diopter range available in powers ranging from 0.0 to +34.0 in 0.5 diopter steps
- Fully preloaded delivery system
Optimized visual outcomes1
The patented ZEISS Optic (ZO) Asphericity Concept of the ZEISS CT LUCIA 621P was developed to compensate for a wide range of spherical aberrations. It is uniquely designed to be less susceptible to decentration enabling optimized visual outcomes.1.
Excellent stability
ZEISS CT LUCIA 621P IOLs feature a reinforced optic-haptic junction, coupled with step-vaulted C-loop haptics, designed to enable easy centering while maximizing direct capsular contact, thus optimizing stability and supporting a consistent position in the bag.
Intuitive injector handling
The ZEISS CT LUCIA 621P is supplied in a fully preloaded delivery system. Based on survey results, the CT LUCIA 621P scored very highly in the preparatory phase and helped to reduce surgery time as it was intuitive and easy to use.4 In addition, the IOL has a heparin-coated2 surface to allow for a smoother injection and unfolding process.
ZEISS CT LUCIA 602
Reliable monofocal hydrophobic, 3-piece-IOL performance
The ZEISS CT LUCIA 602 is the 3-piece member of the CT LUCIA family, featuring the patented ZO Asphericity Concept (ZO: ZEISS Optic) designed to compensate for a range of aberrations, providing better image quality in real-life conditions. CT LUCIA® 602 uses highly stable PVDF haptics, designed to ensure IOL stability in the capsular bag.
Downloads
Handling instructions video
ZEISS CT LUCIA 621P
Smooth and controlled injection
ZEISS CT LUCIA 602
Designed for better capsular bag stability
Specification comparison
ZEISS CT LUCIA family
CT LUCIA® 621P
|
CT LUCIA® 602
|
|
---|---|---|
Optic Design |
Monofocal, aspheric (aberration correcting) |
Monofocal, aspheric (aberration correcting) |
Material |
Hydrophobic acrylic with heparin-coated2 surface |
Hydrophobic acrylic with Polyvinylidene fluoride (PVDF) monofilament haptics |
Optic Diameter |
6.0 mm |
6.0 mm |
Total Diameter |
13.0 mm |
13.0 mm |
Haptic |
Step vaulted |
Angulation 5° |
Lens Design |
Single-piece |
Three-piece |
Incision Size |
2.2 – 2.6 mm (depending on diopter) |
2.8 mm |
Diopter Range |
From 0.0 to +34.0 D, 0.5 D increments |
From +4.0 to +34.0 D, 0.5 D increments |
Company Labeled A-Constant* |
120.2 |
117.7 |
ACD* |
6.29 |
4.8
|
Abbe Number |
51 |
51 |
Refractive Index |
1.49 |
1.49 |
Implantation in |
Capsular bag |
Capsular bag |
Injector / Cartridge Set |
BLUESERT™ 2.2 Injector for diopter range 0.0 to +24.0 |
ZEISS R28 IOL Delivery System with ZEISS Z28 Cartridge IOL |
BLUESERT 2.4 Injector for diopter range +24.5 to +30.0 |
Delivery System for diopter range +4.0 to +34.0 |
|
BLUESERT 2.6 Injector for diopter range +30.5 to +34.0 |
|
|
ZEISS OPHTHALIN
Competitive viscous-cohesive OVD with high zero-shear viscosity5, being part of an efficient cataract workflow.
Get in touch with us!
Receive more information about the product and availability in your country!
-
1
The data is taken from a simulation. The transferability of the results of such a simulation to patients with an actual implanted intraocular lense has not yet been scientifically proven. Whether the simulated impressions correspond to the actual visual impressions must be clarified in future invasive studies.
-
2
The heparin coating on the lens surface has no pharmacological, immunological or metabolic action.
-
3
Clinical Study in US with CT LUCIA 611 of same material did not show any glistenings at 12 months.
-
4
Data on file.
-
5
Viscosity at zero shear at 100.000 mPas.