Presentación científica
Resultados refractivos en ojos con corrección visual por láser posmiopes: fórmula de Barrett True K con Total Keratometry (TK)
22 septiembre 2019
· 3 MIN VER
![]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/myzeiss/peer-insights/free/ophthalmic-diagnostics/324-on-demand-webinar-iol-power-calculation-standard-cases-to-post-laser-vision-correction/g_barrett.jpg/_jcr_content/renditions/original.image_file.100.100.file/g_barrett.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/myzeiss/peer-insights/free/ophthalmic-diagnostics/324-on-demand-webinar-iol-power-calculation-standard-cases-to-post-laser-vision-correction/g_barrett.jpg/_jcr_content/renditions/original.image_file.360.360.file/g_barrett.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/myzeiss/peer-insights/free/ophthalmic-diagnostics/324-on-demand-webinar-iol-power-calculation-standard-cases-to-post-laser-vision-correction/g_barrett.jpg/_jcr_content/renditions/original./g_barrett.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/myzeiss/peer-insights/free/ophthalmic-diagnostics/324-on-demand-webinar-iol-power-calculation-standard-cases-to-post-laser-vision-correction/g_barrett.jpg/_jcr_content/renditions/original./g_barrett.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/myzeiss/peer-insights/free/ophthalmic-diagnostics/324-on-demand-webinar-iol-power-calculation-standard-cases-to-post-laser-vision-correction/g_barrett.jpg/_jcr_content/renditions/original./g_barrett.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/myzeiss/peer-insights/free/ophthalmic-diagnostics/324-on-demand-webinar-iol-power-calculation-standard-cases-to-post-laser-vision-correction/g_barrett.jpg/_jcr_content/renditions/original./g_barrett.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/myzeiss/peer-insights/free/ophthalmic-diagnostics/324-on-demand-webinar-iol-power-calculation-standard-cases-to-post-laser-vision-correction/g_barrett.jpg/_jcr_content/renditions/original./g_barrett.jpg"})
Autor
Prof. Dr. Graham Barrett
Lions Eye Institute, Perth, Australia
Resumen
Fórmula de Barrett True K con Total Keratometry (TK)
El Prof. Dr. Graham Barrett presenta los primeros resultados refractivos de comparación en pacientes posmiopes LASIK utilizando varias fórmulas. Descubrió que la fórmula Barrett True K con Total Keratometry (TK) mejoraba la predicción de resultados en un 6,7 % en comparación con Barrett True K con queratometría clásica.