![]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.100.100.313,0,2188,1875.file/intrabeam-600-1-2.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.360.360.313,0,2188,1875.file/intrabeam-600-1-2.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.768.768.313,0,2188,1875.file/intrabeam-600-1-2.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.1024.1024.313,0,2188,1875.file/intrabeam-600-1-2.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.1280.1280.313,0,2188,1875.file/intrabeam-600-1-2.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.1440.1440.313,0,2188,1875.file/intrabeam-600-1-2.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-1-2.jpg/_jcr_content/renditions/original.image_file.1875.1875.313,0,2188,1875.file/intrabeam-600-1-2.jpg"})
![]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.100.100.313,0,2188,1875.file/intrabeam-600-2-2.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.360.360.313,0,2188,1875.file/intrabeam-600-2-2.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.768.768.313,0,2188,1875.file/intrabeam-600-2-2.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.1024.1024.313,0,2188,1875.file/intrabeam-600-2-2.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.1280.1280.313,0,2188,1875.file/intrabeam-600-2-2.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.1440.1440.313,0,2188,1875.file/intrabeam-600-2-2.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/intrabeam-600-2-2.jpg/_jcr_content/renditions/original.image_file.1875.1875.313,0,2188,1875.file/intrabeam-600-2-2.jpg"})
Caractéristiques
Poste de travail ZEISS INTRABEAM
Poids total avec configuration complète
|
Poids max. 155 kg (341,72 lbs)
|
---|---|
Dimensions
|
900 mm × 1690 mm × 600 mm / 35,43″ × 66,54″ × 23,62″
(largeur × hauteur × profondeur) |
Plages de tension nominales, commutables
|
(115 V) 110 V – 125 V
(230 V) 220 V – 240 V |
Fréquence nominale
|
50 Hz – 60 Hz
|
Puissance connectée
|
300 VA
|
Caractéristiques
Console de commande 600
Poids
|
4,50 kg (9,92 lbs)
|
---|---|
Dimensions
|
305 mm × 89 mm × 381 mm / 12,00″ × 3,50″ × 15,00″
(largeur × hauteur × profondeur) |
Connexion d'alimentation
|
Via un transformateur d'isolation sur le poste de travail
|
Tension d'entrée
|
100 V – 240 V
|
Fréquence nominale
|
50 Hz – 60 Hz
|
Puissance absorbée
|
60 VA
|
Paramètres de fonctionnement sélectionnables : |
40 kV / 40 μA
50 kV / 5, 10, 20 or 40 μA Correspond au courant maximal du tube à rayons X sur toute la plage de tension. |
![]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.100.100.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.360.360.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.768.768.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.1024.1024.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.1280.1280.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.1440.1440.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc34-intrabeam-floor-stand-working-position.jpg/_jcr_content/renditions/original.image_file.1875.1875.313,0,2188,1875.file/nc34-intrabeam-floor-stand-working-position.jpg"})
![]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.100.100.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.360.360.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.768.768.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.1024.1024.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.1280.1280.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.1440.1440.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/intraoperative-radiotherapy-systems/images/nc32-intrabeam-floor-stand-transport-position.jpg/_jcr_content/renditions/original.image_file.1875.1875.313,0,2188,1875.file/nc32-intrabeam-floor-stand-transport-position.jpg"})
Caractéristiques
Statif de sol mobile NC32 INTRABEAM
Tension nominale
|
100 V / 115 V / 230 V
|
---|---|
Fréquence nominale
|
50 - 60 Hz
|
Puissance absorbée
|
400 VA max.
|
Norme électrique
|
IEC 60601-1;
CAN/CSA-C22.2 N° 601.1-M90 |
Classification produit
|
Type B
|
Degré de protection
|
IPX0
|
Classe de protection
|
Classe de protection I
|
Remarque : les informations fournies sur cette page ne présentent qu'un extrait du mode d'emploi. Pour de plus amples informations, veuillez consulter le mode d'emploi approprié dans son intégralité.