![]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-assess-stage_v5.jpg/_jcr_content/renditions/original.image_file.100.56.222,0,3778,2000.file/dense-cataracts-assess-stage_v5.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-assess-stage_v5.jpg/_jcr_content/renditions/original.image_file.360.203.222,0,3778,2000.file/dense-cataracts-assess-stage_v5.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-assess-stage_v5.jpg/_jcr_content/renditions/original.image_file.768.432.222,0,3778,2000.file/dense-cataracts-assess-stage_v5.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-assess-stage_v5.jpg/_jcr_content/renditions/original.image_file.1024.576.222,0,3778,2000.file/dense-cataracts-assess-stage_v5.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-assess-stage_v5.jpg/_jcr_content/renditions/original.image_file.1280.720.222,0,3778,2000.file/dense-cataracts-assess-stage_v5.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-assess-stage_v5.jpg/_jcr_content/renditions/original.image_file.1440.810.222,0,3778,2000.file/dense-cataracts-assess-stage_v5.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-assess-stage_v5.jpg/_jcr_content/renditions/original.image_file.1920.1080.222,0,3778,2000.file/dense-cataracts-assess-stage_v5.jpg"})
Tratamento
Remoção de cataratas densas e gestão eficiente do tempo da intervenção
![Fragmentação do cristalino de uma catarata com o ZEISS miLOOP; imagem cortesia de Florian Kretz, MD, DEU Fragmentação do cristalino de uma catarata com o ZEISS miLOOP; imagem cortesia de Florian Kretz, MD, DEU]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-treat.jpg/_jcr_content/renditions/original.image_file.100.100.953,3,1804,854.file/dense-cataracts-treat.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-treat.jpg/_jcr_content/renditions/original.image_file.360.360.953,3,1804,854.file/dense-cataracts-treat.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-treat.jpg/_jcr_content/renditions/original.image_file.768.768.953,3,1804,854.file/dense-cataracts-treat.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-treat.jpg/_jcr_content/renditions/original.image_file.851.851.953,3,1804,854.file/dense-cataracts-treat.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-treat.jpg/_jcr_content/renditions/original.image_file.851.851.953,3,1804,854.file/dense-cataracts-treat.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-treat.jpg/_jcr_content/renditions/original.image_file.851.851.953,3,1804,854.file/dense-cataracts-treat.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/specialties/ophthalmology/cataract-surgery/dense-cataract/treat/dense-cataracts-treat.jpg/_jcr_content/renditions/original.image_file.851.851.953,3,1804,854.file/dense-cataracts-treat.jpg"})
Fragmentação do cristalino de uma catarata com o ZEISS miLOOP
Experimentar uma tecnologia inovadora para fragmentar cataratas muito rígidas
![ZEISS miLOOP ZEISS miLOOP]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/phacoemulsificationvitrectomysystems/miloop/images/zeiss-miloop.jpg/_jcr_content/renditions/original.image_file.100.75.478,91,1984,1221.file/zeiss-miloop.jpg","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/phacoemulsificationvitrectomysystems/miloop/images/zeiss-miloop.jpg/_jcr_content/renditions/original.image_file.360.270.478,91,1984,1221.file/zeiss-miloop.jpg","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/phacoemulsificationvitrectomysystems/miloop/images/zeiss-miloop.jpg/_jcr_content/renditions/original.image_file.768.576.478,91,1984,1221.file/zeiss-miloop.jpg","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/phacoemulsificationvitrectomysystems/miloop/images/zeiss-miloop.jpg/_jcr_content/renditions/original.image_file.1024.768.478,91,1984,1221.file/zeiss-miloop.jpg","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/phacoemulsificationvitrectomysystems/miloop/images/zeiss-miloop.jpg/_jcr_content/renditions/original.image_file.1280.960.478,91,1984,1221.file/zeiss-miloop.jpg","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/phacoemulsificationvitrectomysystems/miloop/images/zeiss-miloop.jpg/_jcr_content/renditions/original.image_file.1440.1080.478,91,1984,1221.file/zeiss-miloop.jpg","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/phacoemulsificationvitrectomysystems/miloop/images/zeiss-miloop.jpg/_jcr_content/renditions/original.image_file.1506.1130.478,91,1984,1221.file/zeiss-miloop.jpg"})
ZEISS miLOOP
O ZEISS miLOOP permite-lhe:
- Reduzir a energia de facoemulsificação em até 53% para cataratas nucleares de grau 3-4+6
- Diminuir o volume de fluido de irrigação cirúrgico utilizado por caso em até 30%6
- Minimizar o stress na cápsula e zónulas6
- Reduzir o tempo de tratamento na intervenção e no período pós-operatório7
![Portefólio de OVD ZEISS Portefólio de OVD ZEISS]({"xsmall":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/iols-injectors-bss-ovds/ovds/images/zeiss-celcoat-hyalcoat_masked.png/_jcr_content/renditions/original.image_file.100.75.187,398,1865,1659.file/zeiss-celcoat-hyalcoat_masked.png","small":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/iols-injectors-bss-ovds/ovds/images/zeiss-celcoat-hyalcoat_masked.png/_jcr_content/renditions/original.image_file.360.270.187,398,1865,1659.file/zeiss-celcoat-hyalcoat_masked.png","medium":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/iols-injectors-bss-ovds/ovds/images/zeiss-celcoat-hyalcoat_masked.png/_jcr_content/renditions/original.image_file.768.576.187,398,1865,1659.file/zeiss-celcoat-hyalcoat_masked.png","large":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/iols-injectors-bss-ovds/ovds/images/zeiss-celcoat-hyalcoat_masked.png/_jcr_content/renditions/original.image_file.1024.768.187,398,1865,1659.file/zeiss-celcoat-hyalcoat_masked.png","xlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/iols-injectors-bss-ovds/ovds/images/zeiss-celcoat-hyalcoat_masked.png/_jcr_content/renditions/original.image_file.1280.960.187,398,1865,1659.file/zeiss-celcoat-hyalcoat_masked.png","xxlarge":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/iols-injectors-bss-ovds/ovds/images/zeiss-celcoat-hyalcoat_masked.png/_jcr_content/renditions/original.image_file.1440.1080.187,398,1865,1659.file/zeiss-celcoat-hyalcoat_masked.png","max":"https://www.zeiss.com/content/dam/med-hcp/reference-master/product-portfolio/iols-injectors-bss-ovds/ovds/images/zeiss-celcoat-hyalcoat_masked.png/_jcr_content/renditions/original.image_file.1678.1259.187,398,1865,1659.file/zeiss-celcoat-hyalcoat_masked.png"})
Portefólio de OVD ZEISS
A ZEISS tem dois OVD diferentes para revestir os tecidos oculares delicados, dando-lhe a liberdade de escolher entre uma solução moderada e uma abrangente.
ZEISS Z-CELCOAT
OVD dispersivo de baixa viscosidade (HPMC), que protege o endotélio revestindo os tecidos oculares.
ZEISS Z-HYALCOAT
OVD dispersivo de média viscosidade, uma proteção em várias manobras cirúrgicas, proporcionando uma excelente partição do espaço.
Entrar em contacto connosco
-
1
M. Colvard, Phacoemulsification of the rock hard cataract, Eyeworld 2012, https://www.eyeworld.org/article-phacoemulsification-of-the-rock-hard.
-
2
U. Devgan, Dense brunescent cataracts present surgical challenges, Ocular Surgery News 2011, https://www.healio.com/news/ophthalmology/20120331/dense-brunescent-cataracts-present-surgical-challenges.
-
3
S.Garg, Surgeons meet challenges of removing rock-hard cataracts, Ocular Surgery News 2018, https://www.healio.com/news/ophthalmology/20181010/surgeons-meet-challenges-of-removing-rockhard-cataracts.
-
4
https://www.eyeworld.org/phaco-turns-50.
-
5
http://corporate.ewreplay.org/?v=6122661582001.
-
6
Ianchulev T et al. Microinterventional endocapsular nuclear disassembly: novel technique and results of first-in-human randomised controlled study. Br J Ophthalmol 2019;103:176–180.
-
7
A afirmação de redução do tempo de intervenção é decorrente de uma avaliação interna: inquérito pós-comercialização realizado em 2019 n=279; dados em arquivo.
-
8
https://crstodayeurope.com/articles/2020-june/mature-brown-cataract/.
-
9
A.Brissette, OCT Is Indispensable for Pre-op Cataract Evaluation, Opthalmology Management 2019, https://www.ophthalmologymanagement.com/newsletters/insights-into-integrated-diagnostic-imaging/may-2019.
-
10
R. J. Olson, MD, Salt Lake City, Review of Ophtalmology, Publicado a 15 de janeiro de 2005 Demystifying Dysphotopsia.