How-to Video

How to Set up Koehler Illumination

On Your Upright Transmitted Light Microscope

8 April 2020 · 3 min watch
  • Teaching
  • Widefield Light Microscopy

Abstract

You want to image your samples with optimized contrast and resolution?

Then you need to apply Köhler illumination, a process that provides homogeneous illumination without stray light. It still is the only method to obtain reproducible quantitative data in light microscopy.

How-to Video

  • How to Set up Koehler Illumination

    On Your Upright Transmitted Light Microscope

FAQ

  • Koehler illumination is a method in light microscopy to ensure even illumination of the sample and to obtain the clearest possible images. This principle was introduced by August Köhler in 1893 to address issues with non-uniform illumination and poor image quality that were common in microscopy during this time. The Koehler illumination principle involves aligning the illumination so that the light source is focused on the condenser aperture, resulting in an even distribution of light on the specimen and preventing hot spots or shadows. By correctly aligning and adjusting the microscope components - such as the condenser, field diaphragm and aperture diaphragm - researchers can achieve an artefact-free, reproducible image of high quality with uniform background brightness and best resolution of specimen details. In addition, Köhler illumination minimizes stray light and optimizes the image contrast. That makes it an essential technique in all fields of microscopy such as biology, medicine, and materials science as well as for educational fields. For all of them, the reproducible, accurate visual representation of specimens is of utmost importance.

  • Köhler illumination is highly regarded in microscopy due to its numerous advantages, in particular the optimal light distribution and image sharpness. In contrast to other illumination methods, Köhler illumination provides uniform and homogeneous illumination of the entire object field. This is achieved by precisely focusing the light source into the condenser aperture plane and into the objective pupil, allowing clear, detailed and artefact-free visualization of the specimens. This system also minimizes stray light and shadows and reproducibly produces high-contrast images, which are essential for accurate analysis and interpretation of specimen properties. In addition, Köhler illumination maximizes resolution by utilizing the full numerical aperture of the microscope, improving the overall quality and detail of the observed sample. Another significant advantage is its ability to reduce eye strain during prolonged use, as it produces a uniformly bright and comfortable field of view. These features make Köhler illumination indispensable for applications in biological research, clinical diagnostics, material sciences and education where precision, clarity and reproducibility of results are of paramount importance.

  • Köhler illumination should be performed at the beginning of each microscopy session to ensure optimal imaging conditions. Each time a different objective is used, it is necessary to adjust the Köhler illumination setting to accommodate changes in magnification and numerical aperture. In addition, Köhler illumination should be revisited whenever there is a change in the observation conditions of the specimen, as different properties of the sample can affect the light path and clarity. This also applies if the microscope has been moved or if environmental conditions such as temperature fluctuations may have led to a slight shift in the optical components or if optical components have been changed or replaced. Generally, whenever a specimen is viewed or photographed, the Köhler illumination setting must be checked and corrected if necessary. This not only optimizes the image quality, but also ensures that all microscopic observations are accurate and reliable and lead to reproducible and artefact-free results.


Share this video

Contact for Insights Hub

Further Questions?

Please feel free to contact our experts.

Form is loading...

/ 4
Next Step:
  • Step 1
  • Step 2
Required Information

If you want to have more information on data processing at ZEISS please refer to our data privacy notice.