ZEISS Xradia Context microCT
Product

ZEISS Xradia Context MicroCT The Industry’s Most Advanced MicroCT Platform

ZEISS Xradia Context® micro-computed tomography (microCT) is an easy-to-use system for analysis of all types of samples. A high-array detector enables high resolution of fine details even with relatively large imaging volumes. The system features a large field of view, rapid sample mounting and alignment, streamlined acquisition workflow and fast exposure and data reconstruction times.

  • Obtain 3D data on entire intact electronic components, large materials samples, or biological specimens.
  • Perform non-destructive failure analysis to identify internal defects without cutting your sample or workpiece.
  • Characterize and quantify performance-defining heterogeneities in your geo samples, like porosity, cracks, inclusions, defects, or multiple phases.
  • Perform 4D evolutionary studies, through ex situ treatment or in situ sample manipulation.
  • Connect to the ZEISS correlative microscopy environment and perform nondestructive 3D imaging to identify regions of interest for subsequent analysis.
Virtual cutaway view of the interior of an intact catalytic converter

Full Context 3D Imaging

  • Xradia Context provides you with superb image quality, stability, and usability, along with an efficient workflow environment and high throughput scanning
  • Resolve fine details in their full 3D context, even within a relatively large imaging volume, with a high pixel density detector of six megapixels
  • Visualize buried structures non-destructively in 3D for process analysis, construction analysis and failure analysis
  • Maximize geometric magnification with small samples to identify and characterize micron-scale structures with high contrast and clarity
  • Take advantage of a streamlined acquisition workflow fast exposure times and data reconstruction

Virtual cutaway view of the interior of an intact catalytic converter

    Context microCT scan of intact smart watch.

    Based on Proven Xradia Platform

    • With Xradia Context microCT, you benefit from years of development and proven stability as it is built on the same platform as the Xradia Versa series
    • Gain from a system targeted at advances in high resolution, high quality data acquisition and reconstruction
    • The user-friendly Scout-and-Scan control system provides you with an efficient workflow environment
    • Mount and align your specimens rapidly or expand your system with an optional Autoloader for automated handling and sequential scanning of up to 14 samples
    • With the in situ kit, perform 4D and in situ studies to measure changes in the microstructure of materials under varying conditions
    • Add the Advanced Reconstruction Toolkit for even faster throughput with excellent image quality

    Context microCT scan of intact smart watch.

            Full field of view imaging of a bear jaw

            Convertible to Xradia Versa Microscope (XRM)

            • As your imaging needs evolve, so should your instrument. Xradia Context joins the ZEISS X-ray imaging portfolio, benefiting from the ongoing ZEISS commitment to extend the capabilities and functionality of its systems in the field.
            • This opens up 3D tomographic imaging that's ready to grow with your needs: your Xradia Context microCT is the only microCT that can be converted at any time, to CrystalCT, or a 5XX platform, all the way up to ZEISS Xradia 620 Versa 3D X-ray microscope (XRM).

            Full field of view imaging of a bear jaw

                    Fields of Application

                    • 3D Context microCT scan of smart speaker.
                      3D Context microCT scan of smart speaker.

                      Electronics

                      3D Context microCT scan of smart speaker. Visualize buried structures and defects non-destructively in 3D across a wide range of samples sizes with class-leading resolution at chosen field of view.

                    • 3D rendering of a light bulb
                      3D rendering of a light bulb

                      Manufacturing

                      3D rendering of a light bulb. Context can be used to perform full sample scanning to check internal structures or identify defects in manufactured components.

                    • Cutaway view of 3D rendering of a mouse embryo embedded in paraffin
                      Cutaway view of 3D rendering of a mouse embryo embedded in paraffin

                      Life Sciences

                      Cutaway view of 3D rendering of a mouse embryo embedded in paraffin. Internal structures are visible with high contrast. Sample courtesy of Massachusetts General Hospital.

                    • Virtual cross section through a heterogeneous rock sample revealing multiple phases and porosity.
                      Virtual cross section through a heterogeneous rock sample revealing multiple phases and porosity.

                      Geosciences

                      Virtual cross section through a heterogeneous rock sample revealing multiple phases and porosity.

                    • Virtual cross section through a cycled and de-packaged lithium ion battery, revealing damage in the current collector and cathode layers
                      Virtual cross section through a cycled and de-packaged lithium ion battery, revealing damage in the current collector and cathode layers

                      Materials Science

                      Virtual cross section through a cycled and de-packaged lithium ion battery, revealing damage in the current collector and cathode layers. Sample courtesy of Prof. D. U. Sauer and Prof. E. Figgemeier, ISEA, RWTH Aachen University

                    • 3D rendering of results from a rapid scan of a turbine blade to evaluate geometry and inspect for internal defects or cracks.
                      3D rendering of results from a rapid scan of a turbine blade to evaluate geometry and inspect for internal defects or cracks.

                      Metals

                      3D rendering of results from a rapid scan of a turbine blade to evaluate geometry and inspect for internal defects or cracks.

                    Technology Insights

                    • Xradia Context microCT is built on the established and proven Xradia Versa platform
                      Xradia Context microCT is built on the established and proven Xradia Versa platform.

                      Xradia Context microCT is built on the established and proven Xradia Versa platform.

                      Image Quality Based on Proven Technology

                      Experience excellent contrast and image clarity, enabling easy differentiation of different phases and features to support downstream segmentation and quantification of your data.

                      Excellent data quality relies on several factors including source characteristics, beam energy tuning, detector geometry and sensitivity, environmental control, motion and vibrational stability, careful system calibration, and reconstruction accuracy. Xradia Context microCT is built on the same platform as the proven Xradia Versa X-ray microscope series, inheriting the same advancements that helped Xradia Versa set the standard in high-performance 3D X-ray imaging in the laboratory.

                      • Superior high purity X-ray filters to match samples for beam hardening control
                      • Enhanced automated drift correction modes
                      • Advanced beam hardening reduction algorithms
                      • Additional proprietary advanced algorithms to ensure optimal image quality
                    • SmartShield is a solution that protects your sample and your microscope.

                      Easily Protect Your Sample to Optimize Experiment Setup

                      SmartShield is a solution that protects your sample and your microscope. This automated collision avoidance system works within the Scout-and-Scan Control System. It enables you to navigate Xradia Versa more confidently than ever. With the click of a button SmartShield creates a digital protective layer based on the dimensions of your sample.

                      With SmartShield, you benefit from:

                      • Improved operator efficiency enabled by a streamlined sample setup
                      • Enhanced user experience for novice and advanced users
                      • Protection of your valuable samples and your investment
                      • Uncompromising scan quality
                    • Wide Field Mode

                      Wide Field Mode

                      Wide Field Mode (WFM) can be used to image across an extended lateral field of view. The wide lateral field of view can provide 3x larger 3D volume for large samples, or give a higher voxel density for a standard field of view. All Xradia Versa systems are capable of WFM with the 0.4x objective. In combination with Vertical Stitching, WFM enables you to image larger samples at exceptional resolution.

                    Accessories

                    Upgrade your microscope with additional accessories to enhance its capabilities

                    3D X-ray dataset of a camera lens acquired using ZEISS Xradia 620 Versa and DeepRecon Pro.
                    3D X-ray dataset of a camera lens acquired using ZEISS Xradia 620 Versa and DeepRecon Pro.

                    Advanced Reconstruction Toolbox

                    Higher Throughput with Image Quality

                    Artificial intelligence (AI)-driven reconstruction technologies for your ZEISS Xradia systems. A deep understanding of both X-ray physics and applications enable you to solve some of the hardest imaging challenges in new and innovative ways.

                    Autoloader option enables you to program up to 70 samples at a time to run sequentially.
                    Autoloader option enables you to program up to 70 samples at a time to run sequentially.

                    Autoloader

                    Maximize Your Instrument’s Utilization

                    Maximize use and minimize user intervention with the optional ZEISS Autoloader. Reduce the frequency of user interaction and increase productivity by enabling multiple jobs to run. Load up to 14 sample stations, which can support up to 70 samples, queue, and allow to run all day, or off-shift.

                    In Situ Interface Kit
                    In Situ Interface Kit

                    In Situ Interface Kit

                    Push the Limits of Scientific

                    ZEISS Xradia platforms can accommodate a variety of in situ rigs, from high-pressure flow cells to tension, compression, and thermal stages, to user-customized designs. Moving beyond the three dimensions of space, leverage the non-destructive nature of X-ray investigation to extend your studies into the dimension of time with 4D experiments.

                    Lithium ion battery
                    Lithium ion battery

                    Lithium ion battery

                    Visualization and Analysis

                    ZEISS Recommends Dragonfly Pro

                    An advanced analysis and visualization software solution for your 3D data acquired by a variety of technologies including X-ray, FIB-SEM, SEM and helium ion microscopy.​ Available exclusively through ZEISS, ORS Dragonfly Pro offers an intuitive, complete, and customizable toolkit for visualization and analysis of large 3D grayscale data. Dragonfly Pro allows for navigation, annotation, creation of media files, including video production, of your 3D data. Perform image processing, segmentation, and object analysis to quantify your results.

                    Downloads

                      • ZEISS Xradia Context microCT

                        Your X-ray System for Today with Assurance for Tomorrow in English

                        8 MB
                      • 3D X-ray Microscope Field Conversion and Upgrade Options

                        2 MB
                      • Flyer: ZEISS Xradia Context microCT

                        Increase your profitability and productivity with class-leading performance

                        825 KB
                      • Flyer: ZEISS Xradia Context microCT

                        Advance your R&D with high resolution, non-destructive 3D imaging

                        792 KB
                      • ZEISS Mineralogic 3D for Mining - Flyer

                        Your geometallurgy goals realized with maximum efficiency

                        539 KB
                      • ZEISS PhaseEvolve

                        Reveal contrast that has never been seen before

                        1 MB
                      • ZEISS Solutions for Semiconductor Development, Manufacturing, and Analysis

                        Accelerating Digital Transformation and Innovation for Semiconductor Electronics

                        13 MB


                      • Resolution of a 3D X-ray Microscope

                        Defining Meaningful Resolution Parameters

                        932 KB
                      • 3D X-ray Imaging in Life Science Research

                        An Introduction to Capturing the 3D Structure of Biological Specimens Using X-rays

                        3 MB
                      • The building blocks of our solar system

                        Studying the Winchcombe meteorite

                        3 MB


                    Contact ZEISS Microscopy

                    Contact

                    Form is loading...

                    / 4
                    Next Step:
                    • Step 1
                    • Step 2
                    • Step 3
                    Contact us
                    Required Information
                    Optional Information

                    If you want to have more information on data processing at ZEISS please refer to our data privacy notice.