Pósteres ZEISS Vision Care

Os nossos recentes estudos sobre a miopia

2024

Conferência Internacional de Miopia

Nesta área pode encontrar pósteres da ZEISS Vision Care que foram apresentados na Conferência Internacional de Miopia 2024.

Poster Arne Ohlendorf
Arne Ohlendorf et al.

Myopia control efficacy of MyoCare explained by an absolute rather than proportional effect

We demonstrate that efficacy if myopia control strategies including MyoCare is better explained using the absolute difference (in dioptres or mms) between test and control groups rather than using relative efficacy or percent values. Specifically, use of percent (relative or proportional effect) results in over estimation of efficacy for average progressors but underestimates slow as well as fast progressors.

Poster Cristina Alvarez-Peregrina
Cristina Alvarez-Peregrina et al.

One-year results of the CEME Study: Efficacy of MyoCare for myopia control in a European Population

In a 2-year trial assessing the efficacy of MyoCare in European children (CEME) study, 12 – month interim results indicate that MyoCare is able to significantly slow myopia. The children participating in the CEME study will continue to be monitored to provide a more comprehensive evaluation of MyoCare's long-term effectiveness in slowing down the progression of myopia.

2024

ARVO

Nesta área pode encontrar todos os pósteres da ZEISS Vision Care que foram apresentados no ARVO 2024. Disponibilizamos aqui um resumo de todos os resultados do estudo. Se procura informações da ZEISS Medical Technology, siga este link. 

Poster Cristina Alvarez-Peregrina
Cristina Alvarez-Peregrina et al.

Efficacy of a next-generation design of ophthalmic lenses for myopia control: 6-month results of the CEME Study

Interim analysis with the next-generation myopia control spectacle lens with C.A.R.E. technology from the CEME study demonstrated to be efficient over six months. Children will continue to be monitored after one and two years of lens wear for a more comprehensive evaluation of the long-term efficacy of the C.A.R.E. spectacle lens in slowing the progression of myopia.

Poster Xiaoqin Chen
Xiaoqin Chen et al.

Slowing myopia progression with cylindrical annular refractive elements (C.A.R.E.) – 12-month interim results from a 2-year prospective multi-center trial

In children with myopia, after twelve months of lens wear, both ZEISS MyoCare and ZEISS MyoCare S were found to significantly slow myopia progression compared to single vision lenses.

Poster Padmaja Sankaridurg
Padmaja Sankaridurg et al.

Probability of surviving fast progression and eye growth reversal after 1-year of spectacle wear with cylindrical annular refractive elements

Probability of surviving fast progression was greater with ZEISS MyoCare than single vision. Whilst 51% of single vision eyes experienced fast progression ( -0.75D or worse) in myopia after twelve months, only 17% of ZEISS MyoCare and 14% of ZEISS MyoCare S wearing eyes experienced fast progression.

Poster Arne Ohlendorf
Arne Ohlendorf et al.

Myopia control efficacy through Emmetropic Progression Ratio: 1-year of spectacle wear with cylindrical annular refractive elements (C.A.R.E.)

Emmetropic Progression Ratio (EPR) demonstrates that ZEISS MyoCare and ZEISS MyoCare S reduced myopic axial length growth by an average of 70% and 68% compared to emmetropic eye growth. Seven of ten eyes wearing ZEISS MyoCare or ZEISS MyoCare S had eye growth similar to or equivalent to emmetropic eyes.

Poster Christina Boeck-Maier
Christina Boeck-Maier et al.

Impact of parental myopia on myopia control efficacy of spectacle lenses with cylindrical annular refractive elements (C.A.R.E.)

In children wearing single vision spectacle lenses, myopia progressed faster in those with parental myopia. In comparison, in children wearing spectacle lenses incorporating C.A.R.E., myopia progression was not significantly related to parental myopia.

Poster Katharina Rifai
Katharina Rifai et al.

Subjective acceptance of spectacle lenses with cylindrical annular refractive elements (C.A.R.E.) in Chinese children with myopia

High daily wear time was reported with myopic children wearing speacacle lenses incorporating cylindrical annular refractive elements (C.A.R.E.) and no wear time difference compared to single vision lenses. Subjective evaluation of vision for different distances and activities revealed high subjective acceptance, comparable to single vision lenses.

ZEISS MyoCare e ZEISS MyoCare S não estão disponíveis em USA.


Partilhar esta página