ZEISS Subjective Refraction Unit
ZEISS FOR EYE CARE PROFESSIONALS

ZEISS VISUSCREEN 100/500 and VISUPHOR 500 A new perspective in subjective refraction.

ZEISS Subjective Refraction Unit (SRU) (consisting of ZEISS VISUPHOR 500 and ZEISS VISUSCREEN 100 or 500) reduces refraction time and stress, offering you and your patients a truly convenient vision testing experience.

  • Earn patients’ trust by using advanced technology
  • Focus on the unique needs of every patient
  • A new perspective in subjective refraction
ZEISS Subjective Refraction Unit saves time in the refraction process and reduces the risk of significant deviations.

ZEISS Subjective Refraction Unit saves time in the refraction process and reduces the risk of significant deviations.

Take advantage of the new  built-in refraction logic and of the supportive control elements and functions, e.g. fogging buttons, and the automatically inserted age-related addition to speed up your examination.

  • On average, ZEISS Subjective Refraction Unit offers 18 % faster refraction compared to a manual phoropter, and 24 % faster refraction compared to a trial frame.1
  • ZEISS Subjective Refraction Unit reduces the risk of significant deviation within subjective refraction by 50 % compared to a manual phoropter, and by 70 % compared to a trial frame.1
Secure patients’ trust by performing refraction with advanced vision-testing technology.

Secure patients’ trust by performing refraction with advanced vision-testing technology.

  • Combine ZEISS refraction instruments to perform an examination room experience that delivers highly precise results your patient can trust.
  • The fully integrated Graphical User Interface allows both the phoropter and visual acuity screen to be controlled simultaneously and wirelessly. This allows the user to single-handedly operate while ensuring a safe social distance.
  • Get accurate results with minimum subjective dependency on your patients.
  • Customise several workflows and compare different prescriptions with just one click.
  • Connecting objective and subjective refraction devices to the practice is possible with ZEISS VISUCONSULT 500. It is easy and convenient and enables a completely paperless workflow, eliminating error-prone manual data entry and inevitably increasing staff efficiency.
  • Patient data can be stored centrally, making it remotely accessible to any member of staff, at any time.
Focus on the unique needs of every patient.

Focus on the unique needs of every patient.

  • Smart and preconfigured workflows let you get right down to work.
  • Choose one of up to six default workflows or customise your own personalised workflow.
  • Streamlined workflow in the examination room creates a professional impression for your patient.
  • With more than 130 test charts, the examination you need is always at hand – you can easily create a "binocular" or "near vision" refraction workflow along with many more.
  • Integrated LED as additional charts feature for the Maddox test and ZEISS i.Scription Technology demonstration.
  • Fast and smooth exchange of inspection lenses allows real-time demonstration of final prescription and vision improvement.
A new perspective in subjective refraction.

A new perspective in subjective refraction.

  • Fits into small examination rooms with  a distance of 2  m in indirect use, supported by an automated size adjustment of the optotypes for the distance used.

  • Flat-screen design with a premium glass front panel prevents steps or shadows.

  • Crystal clear LCD screen with  polarised  technology (ZEISS VISUSCREEN 500) or red/green separation (ZEISS VISUSCREEN 100).

  • Integrated LED as an additional test feature for the Maddox test and ZEISS  i.Scription  technology demonstration.

  • Fast and smooth exchange of inspection lenses allows real-time demonstration of final prescription and vision improvement.

  • The Subjective Refraction Unit can be linked to ZEISS VISULENS  550, ZEISS VISUREF  150  and ZEISS  i.Profiler plus for direct data transfer via ZEISS VISUCONSULT 500.

ZEISS VISUSCREEN 100/500

Technical specifications

Test area size (W x H)
299.5 x 223.5 mm
Testing distance
1 to 8 m
Polarisation directions for analysers2
Right eye: 45° / left eye: 135°

ZEISS VISUPHOR 500

Technical specifications

Spherical lenses
–29.00 to +26.75 D
–19.00 to +16.75 D (when using a cross cylinder or a prism) (steps of 0.125 D)
Cylinder lenses
0 to ± 8.75 D (steps of 0.25 D)
Cylinder axis
0 to 180° (increments: 1° steps)
Cross cylinder
± 0.25 D
± 0.50 D
± 0.25 D (dual cross cylinder)
PD
48 to 80 mm (steps of 0.25 mm)
Rotary prism
0 to 20 Δ
Retinoscopy
+1.5 D, +2.0 D
Pinhole lens
2 mm
Maddox rod
Right eye: red, horizontal / left eye: red, vertical
Red/green filter
Right eye: red / left eye: green
Polarising filter
Right eye: 135°, 45° / left eye: 45°, 135°
Split prism
Right eye: 6 Δ BU / left eye: 10 Δ BI (up to 5 Δ complement)

ZEISS VISUSCREEN 100/500 and ZEISS VISUPHOR 500

Physical data

ZEISS VISUSCREEN 100/500
ZEISS VISUPHOR 500
Line voltage
100 – 240 V AC; ± 10%, 50…60 Hz
100 – 120 / 200 – 240 V AC; ± 10%, 50…60 Hz
Power consumption
50 VA
145 VA
Dimensions (W x H x D)
594 x 594 x 110 mm
361 x 280 x 108 mm
Weight
16 kg
5 kg
Interfaces
1x USB / WLAN
2x RS232 / Bluetooth
System requirements
iPad 3, 4 or Air with iOS 7 or later
iPad 3, 4 or Air with iOS 7 or later

Contact Us

How can we help you?

Form is loading...

Contact us

The information entered in the contact form will be used to answer your request by Carl Zeiss Vision International GmbH by E-Mail or phone. Click here to read our statement on data protection.

Further Information

Product | ZEISS Medical Device
Legal manufacturer
Legal distributor

VISUCORE 500 Refractor*

CZV

VISUCORE 500 Table

CXE

CZV

VISUSCREEN 100 Compact

CZV

VISUFIT 1000 Platform
CZV
VISUFIT 1000 *
CZV
VISUCONSULT 500

CZV

VISUPLAN 500 *
CZM

CZV

VISUSCOUT 100 **
OO
CZV
i.Profiler plus*
CZV
VISUREF 150 *
CZM
CZV
VISUPHOR 500
CZM
CZV
VISUSCREEN 100/500
CZV
i.Terminal 2 Station
CZV
i.Terminal 2 *
CZV
i.Terminal mobile *
CZV
ZEISS Slit Lamps
CZM
CZV

Slit Lamp Imagine Solution

CZM

CZV

VISULENS 550
CZM
CZV
VISU360
CZV
ATLAS Review for i.Profiler plus *
CZV
Product | ZEISS non-Medical Device
Virtual Try-on
CZV
Avatar Generation
CZV
VISUSTORE
CZV
i.Terminal go
CZV

i.Com classic

CZV

i.Com mobile

CZV

International edition: only for sale in selected countries.
Please contact your local sales manager for more information.

  
VISUCORE, VISULENS, VISUCONSULT, VISUPLAN, VISUSCOUT,  i.Profiler, VISUREF, VISUPHOR, VISUSCREEN, VISUFIT, i.Terminal, VISU360 and VISUSTORE are either trademarks or registered trademarks of Carl Zeiss AG or any other companies of the ZEISS Group in Germany and other countries.

  
iPad is a trademark and/or registered trademark of Apple Inc. iOS is a trademark and/or registered trademark of Cisco in the U.S. and other countries and is used under license. Windows®, and the Windows logo are registered trademarks of Microsoft Corporation in the United States and/or other countries.

Carl Zeiss Vision GmbH © All rights reserved.  2023

CZV
Carl Zeiss Vision GmbH
Turnstrasse 27
73430 Aalen
Germany
www.zeiss.com/vision

CZM
Carl Zeiss Meditec AG
Goeschwitzer Strasse 51-52
07745 Jena
Germany
www.zeiss.com/meditec

OO
Optomed Oyj
Yrttipellontie 1
FI-90230 Oulu
Finland

CXE
CX ENGINEERING sp.zo.o.
ul. Przemyslowa 17
32-083 Balice
Poland


  • 1

    ZEISS Vision Science Lab/Uni Tübingen and CZV study,n= 22 subjects, October 2017

  • 2

    for VISUSCREEN 500 only